Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.009
Filtrar
1.
Wiad Lek ; 77(2): 201-207, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38592979

RESUMO

OBJECTIVE: Aim: To investigate a correlation between cervical ripening, the immunological features and the hemodynamic characteristics of the cervix during the preparation for vaginal labor. PATIENTS AND METHODS: Materials and Methods: We examined 75 pregnant women at different gestational age. General clinical and immunological studies were conducted in order to check serum concentration of cytokines IL-6, IL-1ß, and TNF-α. Ultrasound and Doppler study were used to determine resistance index and systolic-diastolic ratio of blood flow in the common uterine artery as well as the descending and ascending parts and cervical stromal arteries. RESULTS: Results: Pregnant women with high cervical ripening score had high concentrations of the major proinflammatory cytokines (IL-1ß, IL-6, and TNF-α). Analysis of the of the cervical blood flow indicators of the studied groups showed significant differences in the indices of vascular resistance in the vessels that feed the cervix. Our data showed a significant correlation between the cervix ripening and both the serum levels of the studied cytokines and the level of peripheral vascular resistance indices in the common uterine arteries of the cervix, and the blood flow indices in the cervical stromal vessels. CONCLUSION: Conclusions: Our study shows that the process of preparing the woman's body for labor is associated with immunological adjustment and increased hemodynamics of the cervix. We report that cervical ripening is associated with the immunological components and hemodynamic parameters of the cervix at late-stage pregnancy. Measuring cervix ripening and the accompanied changes in cytokine levels and hemodynamic parameters will form a more accurate assessment of birth preparedness and labor complications.


Assuntos
Colo do Útero , Gestantes , Gravidez , Feminino , Humanos , Colo do Útero/diagnóstico por imagem , Colo do Útero/fisiologia , Maturidade Cervical , Fator de Necrose Tumoral alfa , Interleucina-6 , Citocinas , Hemodinâmica
2.
Am J Obstet Gynecol MFM ; 6(5S): 101267, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38642994

RESUMO

BACKGROUND: Preterm birth is a major cause of perinatal morbidity and mortality. It is unclear whether the introduction of a universal transvaginal ultrasound cervical length screening program in women at low risk for preterm delivery is associated with a reduction in the frequency of preterm birth. OBJECTIVE: To test the hypothesis that the introduction of a midtrimester universal transvaginal ultrasound cervical length screening program in asymptomatic singleton pregnancies without prior preterm delivery would reduce the rate of preterm birth at <37 weeks of gestation. STUDY DESIGN: This study was a multicenter nonblinded randomized trial of screening of asymptomatic singleton pregnancies without prior spontaneous preterm birth, who were randomized to either cervical length screening program (ie, intervention group) or no screening (ie, control group). Participants were randomized at the time of their routine anatomy scan between 18 0/7 and 23 6/7 weeks of gestation. Women randomized in the screening group received cervical length measurement. Those who were found to have cervical length ≤25 mm were offered 200 mg vaginal progesterone daily along with cervical pessary. The primary outcome was preterm birth at <37 weeks. The risk of primary outcome was quantified by the relative risk with 95% confidence interval, and was based on the intention-to-screen principle. RESULTS: A total of 1334 asymptomatic women with singleton pregnancies and without prior preterm birth, were included in the trial. Out of the 675 women randomized in the transvaginal ultrasound cervical length screening group, 13 (1.9%) were found to have transvaginal ultrasound cervical length ≤25 mm during the screening. Preterm birth at <37 weeks of gestation occurred in 48 women in the transvaginal ultrasound cervical length screening group (7.5%), and 54 women in the control group (8.7%) (relative risk, 0.86; 95% confidence interval, 0.59-1.25). Women randomized in the transvaginal ultrasound cervical length screening group had no significant differences in the incidence of preterm birth at less than 34, 32, 30, 28, and 24 weeks of gestation. CONCLUSION: The introduction of a universal transvaginal ultrasound cervical length screening program at 18 0/6 to 23 6/7 weeks of gestation in singleton pregnancies without prior spontaneous preterm birth, with treatment for those with cervical length ≤25 mm, did not result in significant lower incidence of preterm delivery than the incidence without the screening program.


Assuntos
Nascimento Prematuro , Gravidez , Recém-Nascido , Feminino , Humanos , Nascimento Prematuro/diagnóstico , Nascimento Prematuro/epidemiologia , Nascimento Prematuro/prevenção & controle , Risco , Colo do Útero/diagnóstico por imagem , Incidência
4.
BMC Pregnancy Childbirth ; 24(1): 293, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641821

RESUMO

BACKGROUND: Placenta accreta spectrum often leads to massive hemorrhage and even maternal shock and death. This study aims to identify whether cervical length and cervical area measured by magnetic resonance imaging correlate with massive hemorrhage in patients with placenta accreta spectrum. METHODS: The study was conducted at our hospital, and 158 placenta previa patients with placenta accreta spectrum underwent preoperative magnetic resonance imaging examination were included. The cervical length and cervical area were measured and evaluated their ability to identify massive hemorrhage in patients with placenta accreta spectrum. RESULTS: The cervical length and area in patients with massive hemorrhage were both significantly smaller than those in patients without massive hemorrhage. The results of multivariate analysis show that cervical length and cervical area were significantly associated with massive hemorrhage. In all patients, a negative linear was found between cervical length and amount of blood loss (r =-0.613), and between cervical area and amount of blood loss (r =-0.629). Combined with cervical length and cervical area, the sensitivity, specificity, and the area under the curve for the predictive massive hemorrhage were 88.618%, 90.209%, and 0.890, respectively. CONCLUSION: The cervical length and area might be used to recognize massive hemorrhage in placenta previa patients with placenta accreta spectrum.


Assuntos
Placenta Acreta , Placenta Prévia , Gravidez , Feminino , Humanos , Placenta Prévia/diagnóstico por imagem , Placenta Prévia/cirurgia , Placenta Acreta/cirurgia , Colo do Útero/diagnóstico por imagem , Perda Sanguínea Cirúrgica , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Placenta
5.
Am J Obstet Gynecol MFM ; 6(5S): 101343, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38479489

RESUMO

OBJECTIVE: To evaluate the risk of spontaneous preterm birth with or without universal transvaginal ultrasound cervical length screening at the time of midtrimester scan. DATA SOURCES: Medline, Embase, ClinicalTrials.gov, and Web of Science were systematically searched from the inception of the databases to November 12, 2023, using combinations of the relevant medical subject heading terms, key words, and word variants that were considered suitable for the topic. STUDY ELIGIBILITY CRITERIA: Studies including individuals with singleton gestations at 16-25 weeks of gestation screened or not screened with universal transvaginal ultrasound cervical length screening were considered eligible. Primary outcome was spontaneous preterm birth <37 weeks; secondary outcomes were spontaneous preterm birth <34 and <32 weeks. METHODS: Random effect head-to-head analyses were used to directly compare each outcome, expressing the results as summary odds ratio and relative 95% confidence interval. The quality of the included studies was independently assessed by 2 reviewers, using the Newcastle-Ottawa scale for cohort studies and the Cochrane risk-of-bias tool for randomized controlled studies. The study was registered on the prospective register of systematic reviews database (PROSPERO) (registration number: CRD42022385325). RESULTS: Eight studies, including 447,864 pregnancies, were included in the meta-analysis (213,064 screened with transvaginal ultrasound cervical length and 234,800 unscreened). In the overall analysis, universal transvaginal ultrasound cervical length did not significantly decrease the spontaneous preterm birth rates <37 weeks (odds ratio, 0.92 [95% confidence interval, 0.84-1.01], P=.07) and <34 weeks (odds ratio, 0.87 [95% confidence interval, 0.73-1.04], P=.12), but was significantly associated with a lower risk of spontaneous preterm birth <32 weeks (odds ratio, 0.84 [95% confidence interval, 0.76-0.94], P=.002). Individuals without a prior spontaneous preterm birth had a significantly lower risk of spontaneous preterm birth <37 weeks (odds ratio, 0.88 [95% confidence interval, 0.79-0.97], P=.01) and a lower trend of spontaneous preterm birth <32 weeks (odds ratio, 0.82 [95% confidence interval, 0.66-1.01], P=.06) when screened with transvaginal ultrasound cervical length, compared with no screening. CONCLUSION: Universal transvaginal ultrasound cervical length screening usually <24 weeks in singletons without a prior spontaneous preterm birth, is associated with a significant reduction in spontaneous preterm birth <37 weeks, compared with no screening.


Assuntos
Nascimento Prematuro , Gravidez , Feminino , Recém-Nascido , Humanos , Nascimento Prematuro/diagnóstico , Nascimento Prematuro/epidemiologia , Nascimento Prematuro/etiologia , Colo do Útero/diagnóstico por imagem , Estudos de Coortes , Ultrassonografia
6.
Medicine (Baltimore) ; 103(7): e37202, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38363949

RESUMO

BACKGROUND: Uterine prolapse is a rare complication of pregnancy, and there is still no consensus on the choice of delivery method. METHODS: The patient's reproductive history included an abortion and eutocic delivery of a girl weighing 3200 g; the current pregnancy was the third pregnancy. Her cervical region was outside the vaginal opening and was red in color, with evident enlargement (6 × 4 cm) and a broken surface. The cervical area also showed white discharge. According to her Transvaginal ultrasonography revealed a fetus in the uterine cavity at approximately 19 weeks of gestation. Gynecological examination revealed prolapse of both the anterior and posterior vaginal walls. Evaluation of the pelvic organ prolapse-Q scores showed that the patient had uterine prolapse at stage IV. RESULTS: Vaginal delivery was performed smoothly after oral administration mifepristone and misoprostol tablets for a few days, obtaining a dead female fetus in cephalic, 25 cm in length. The cervix of the pregnant woman did not prolapse during the delivery. CONCLUSION: For pregnancy with uterine prolapse and cervical incarceration, transvaginal delivery is a potential treatment option. Maintenance of cervical retraction and oral mifepristone administration with misoprostol tablets is crucial during this delivery. This treatment can minimize the risk of cervical lacerations and uterine rupture, helping surgeons to complete the operation successfully.


Assuntos
Misoprostol , Prolapso Uterino , Humanos , Gravidez , Feminino , Segundo Trimestre da Gravidez , Mifepristona , Prolapso Uterino/complicações , Prolapso Uterino/cirurgia , Colo do Útero/diagnóstico por imagem , 60648 , Parto Obstétrico
7.
Am J Obstet Gynecol MFM ; 6(5S): 101303, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38309643

RESUMO

An accurate transvaginal ultrasound cervical length is paramount to obtain the best prediction for preterm birth. Transvaginal ultrasound cervical length should be optimally obtained when a lower uterine segment contraction is not seen. For universal transvaginal ultrasound cervical length screening at approximately 20 weeks of gestation, the options are to do the transvaginal ultrasound soon after bladder void (lower uterine segment contractions present in 16%-43% of this approach) or to wait until the end of the anatomy scan (ideally within 30 minutes after bladder voiding) to decrease the chance of a lower uterine segment contraction. If the lower uterine segment contraction persists even after waiting up to 20 minutes or more, only the true transvaginal ultrasound cervical length should be reported. In particular, in patients with a previous spontaneous preterm birth, if the lower uterine segment contraction persists, the transvaginal ultrasound cervical length can be repeated in ≤7 days even in the presence of a normal (>25 mm) cervical length. Similar to a blood pressure cuff that must be of the right size for proper blood pressure measurement and a glucometer that must be properly calibrated, screening with transvaginal ultrasound cervical length should only be performed following a proper and standardized technique, including avoiding as much as feasible the presence of lower uterine segment contractions.


Assuntos
Nascimento Prematuro , Feminino , Humanos , Recém-Nascido , Nascimento Prematuro/epidemiologia , Incidência , Colo do Útero/diagnóstico por imagem , Útero/diagnóstico por imagem , Ultrassonografia
8.
Magn Reson Imaging ; 107: 47-54, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38218204

RESUMO

OBJECTIVE: To provide insight into the biological characteristics of the healthy cervix by defining intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) parameters across the menstrual cycle. METHODS: Forty-three females of reproductive age (18-45 years old) were included in this prospective study. Conventional magnetic resonance imaging (MRI) and IVIM-DWI scans were performed at multiple time-points across the menstrual cycle: T1 (menses), T2 (follicular phase), T3 (luteal phase). Intra- and interobserver repeatability of the IVIM-DWI values were evaluated with intraclass correlation coefficients (ICC), and D* was excluded from the analyses due to poor repeatability. Differences in each IVIM-DWI parameter among T1, T2, and T3 were explored. Subjects were stratified by age and parity for subgroup analyses (younger [18 - < 30 years] vs. older [≥30-45 years]; parity 0 vs. parity 1 and 2). Correlations between subject age and IVIM-DWI parameters were assessed. The overlap for each IVIM-DWI parameter among T1, T2, and T3 was evaluated. RESULTS: ADC and D values of the cervix were significantly lower at T3 compared with T1 (p = 0.02 and 0.03) or T2 (p < 0.01 and < 0.01). In younger subjects (n = 26), ADC and D values were significantly lower at T3 compared with T1 (p < 0.01 and p = 0.02) or T2 (p = 0.03 and p = 0.04). In older subjects (n = 17), ADC values were significantly higher at T2 compared with T1 (p = 0.01) or T3 (p = 0.01). There were significant differences in ADC values at T1 in subgroup analyses stratified by age and parity (both p < 0.01). There was a moderate correlation between age and ADC values at T1. Overlap for IVIM-DWI parameters across the menstrual cycle was >50%. CONCLUSION: ADC and D values of the heathy cervix differed across the menstrual cycle. Age and parity may influence the ADC value.


Assuntos
Colo do Útero , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Idoso , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Estudos Prospectivos , Colo do Útero/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Ciclo Menstrual , Movimento (Física)
9.
Arch Gynecol Obstet ; 309(4): 1585-1595, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38282023

RESUMO

STUDY OBJECTIVE: This study aims to evaluate the role of cervical elastography in the differential diagnosis of preinvasive and invasive lesions of the cervix. MATERIALS AND METHODS: A total of 95 women participated in this prospective study and were divided into the following groups: 19 healthy subjects (group 1) with normal cervicovaginal smear (CVS) and negative human papillomavirus test (HPV DNA), 19 women with normal cervical biopsy and normal final pathological result of cervical biopsy (group 2), 19 women with low-grade squamous intraepithelial lesion (LSIL) (group 3), 19 women with high-grade squamous intraepithelial lesion (HSIL) (group 4), and 19 women with cervical cancer (group 5). Clinical, demographic, histopathological, and elastographic results were compared between these groups. RESULTS: Comparing groups, age (40.42 ± 8.31 vs. 39.53 ± 8.96 vs. 38.79 ± 9.53 vs. 40.74 ± 7.42 vs. 54.63 ± 12.93, p < 0.001 respectively), gravida (1.74 ± 1.33 vs. 2.16 ± 1.68 vs. 2.21 ± 1.96 vs. 2.53 ± 1.93 vs. 4.63 ± 2.17 p < 0.001 respectively), parity (1.37 ± 0.68 vs. 1.68 ± 1.20 vs. 1.58 ± 1.30 vs. 2.00 ± 1.67 vs. 3.37 ± 1.61, p < 0.001 respectively), and the proportion of patients at menopause (10.5% vs., 15.8% vs. 10.5% vs. 5.3% vs. 57.9%, p < 0.01 respectively), a statistically significant difference was found (Table 1). However, no statistically significant difference was found in the number of abortions, BMI, mode of delivery, smoking, additional disease status, history of surgery, and family history (p > 0.05) (Table  2. As a result of the applied roc analysis, mean cervical elastographic stiffness degree (ESD) was found to be an influential factor in predicting cervical cancer (p < 0.05). The mean cut-off value was 44.65%, with a sensitivity of 94.7% and a specificity of 96.1% (Table 7). CONCLUSION: Measurement of ESD by elastography is a low-cost, easily applicable, and non-invasive indicator that can distinguish cervical cancer from normal cervical and preinvasive lesions. However, it is unsuitable for determining preinvasive cervical lesions from normal cervix.


Assuntos
Técnicas de Imagem por Elasticidade , Infecções por Papillomavirus , Lesões Intraepiteliais Escamosas Cervicais , Displasia do Colo do Útero , Neoplasias do Colo do Útero , Gravidez , Humanos , Feminino , Colo do Útero/diagnóstico por imagem , Colo do Útero/patologia , Neoplasias do Colo do Útero/patologia , Displasia do Colo do Útero/patologia , Estudos Prospectivos , Diagnóstico Diferencial , Papillomaviridae/genética , Esfregaço Vaginal , Lesões Intraepiteliais Escamosas Cervicais/diagnóstico
10.
Am J Obstet Gynecol MFM ; 6(5S): 101282, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38242499

RESUMO

OBJECTIVE: This study aimed to evaluate the differences in first-trimester and early-second-trimester transvaginal cervical length between patients with spontaneous preterm birth and those with term birth. DATA SOURCES: PubMed, MEDLINE, Embase, and the Cochrane Library were systematically searched through August 2023. STUDY ELIGIBILITY CRITERIA: Studies had to include (1) transvaginal cervical length measurement before 16+0 weeks of gestation and (2) transvaginal cervical length measurement in a population of patients who delivered preterm and at term. Abstracts, studies with duplicated data, and those with cervical length measured by transabdominal ultrasound scan were excluded. METHODS: K.W.C. and J.L. searched for, screened, and reviewed the articles independently. The quality of the studies was assessed using the Newcastle-Ottawa scale. Mean differences were calculated using a random-effects model and pooled through a meta-analysis. RESULTS: A total of 5727 published articles were identified. Only 10 studies (which analyzed 22,151 pregnancies) met the inclusion criteria. All studies excluded iatrogenic preterm birth. Transvaginal cervical length was significantly shorter in women with spontaneous preterm birth than in those who delivered at term (mean difference, -0.97; 95% confidence interval, -1.65 to -0.29; P=.005; I2=69%). When a linear technique was used to measure transvaginal cervical length, a significantly shorter transvaginal cervical length was associated with spontaneous preterm birth as opposed to term birth (mean difference, -1.09; 95% confidence interval, -1.96 to -0.21; P=.02; I2=77%). A shorter transvaginal cervical length measured by other techniques was also associated with spontaneous preterm birth before 34 to 35 weeks (mean difference, -1.87; 95% confidence interval, -3.04 to -0.70; P=.002; I2=0%). When studies where interventions were given for a "short" cervix or studies with a mean transvaginal cervical length ≥40 mm were excluded, a significantly shorter transvaginal cervical length was observed among those with spontaneous preterm birth (mean difference, -1.13; 95% confidence interval, -1.89 to -0.37; P=.004; mean difference, -0.86; 95% confidence interval, -1.67 to -0.04; P=.04; respectively). The optimal transvaginal cervical length cutoff was 38 to 39 mm, yielding pooled sensitivity of 0.80, specificity of 0.45, positive likelihood ratio of 1.16, negative likelihood ratio of 0.33, diagnostic odds ratio of 5.12, and an area under the curve of 0.75. CONCLUSION: Women with spontaneous preterm birth had significantly shorter transvaginal cervical length before 16 weeks of gestation compared with those who delivered at term. The linear method and the 2-line method are acceptable techniques for measuring transvaginal cervical length.


Assuntos
Colo do Útero , Nascimento Prematuro , Gravidez , Recém-Nascido , Humanos , Feminino , Segundo Trimestre da Gravidez , Colo do Útero/diagnóstico por imagem , Nascimento Prematuro/diagnóstico , Nascimento Prematuro/epidemiologia , Nascimento Prematuro/etiologia , Primeiro Trimestre da Gravidez , Nascimento a Termo
11.
J Biomed Opt ; 29(5): 052918, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38282917

RESUMO

Significance: Preterm birth is defined as a birth before 37 weeks of gestation and is one of the leading contributors to infant mortality rates globally. Premature birth can lead to life-long developmental impairment for the child. Unfortunately, there is a significant lack of tools to diagnose preterm birth risk, which limits patient care and the development of new therapies. Aim: To develop a speculum-free, portable preterm imaging system (PPRIM) for cervical imaging; testing of the PPRIM system to resolve polarization properties of birefringent samples; and testing of the PPRIM under an IRB on healthy, non-pregnant volunteers for visualization and polarization analysis of cervical images. Approach: The PPRIM can perform 4×3 Mueller-matrix imaging to characterize the remodeling of the uterine cervix during pregnancy. The PPRIM is built with a polarized imaging probe and a flexible insertable sheath made with a compatible flexible rubber-like material to maximize comfort and ease of use. Results: The PPRIM device is developed to meet specific design specifications as a speculum-free, portable, and comfortable imaging system with polarized imaging capabilities. This system comprises a main imaging component and a flexible silicone inserter. The inserter is designed to maximize comfort and usability for the patient. The PPRIM shows high-resolution imaging capabilities at the 20 mm working distance and 25 mm circular field of view. The PPRIM demonstrates the ability to resolve birefringent sample orientation and full field capture of a healthy, non-pregnant cervix. Conclusion: The development of the PPRIM aims to improve access to the standard of care for women's reproductive health using polarized Mueller-matrix imaging of the cervix and reduce infant and maternal mortality rates and better quality of life.


Assuntos
Nascimento Prematuro , Gravidez , Lactente , Criança , Recém-Nascido , Feminino , Humanos , Qualidade de Vida , Colo do Útero/diagnóstico por imagem
13.
J Obstet Gynaecol Res ; 50(1): 47-54, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37916525

RESUMO

AIM: This study aimed to evaluate the effect of preinduction cervical length (CL) measurement by transvaginal (TV), transperineal (TP), and transabdominal (TA) ultrasonography (USG) on the time of delivery and to compare these three sonographic methods in terms of superiority over one another. METHODS: This study included TV, TP, and TA CL measurements in pregnant women who were planned to undergo induction of labor at 37 weeks' gestation or later. The correlations between the said three methods and BISHOP scores were evaluated. These three methods were compared in terms of superiority in predicting the time of delivery. RESULTS: Pregnant women at 37-42 weeks' gestation undergoing labor induction were included, and all three methods were used for CL measurements. Three methods were correlated with each other (p < 0.001) and with BISHOP scores (p < 0.001). CONCLUSION: The correlation between all three methods and BISHOP scores indicates that TP and TA USG can be used instead of TV USG. On the other hand, while TA USG did not give a clear result in the accurate estimation of vaginal delivery time, TP, and TV USG gave both accurate and close results. When all these data are evaluated, it is concluded that TPU can be used safely instead of TVU, especially in patients receiving induction.


Assuntos
Medida do Comprimento Cervical , Colo do Útero , Gravidez , Feminino , Humanos , Medida do Comprimento Cervical/métodos , Colo do Útero/diagnóstico por imagem , Parto Obstétrico/métodos , Vagina/diagnóstico por imagem , Idade Gestacional , Trabalho de Parto Induzido , Valor Preditivo dos Testes
14.
J Obstet Gynaecol Res ; 50(1): 65-74, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37903492

RESUMO

OBJECTIVES: The aim of this study was to evaluate the relationship between the cervix and the threat of preterm labor in singleton pregnancies between gestational weeks less than 37 and greater than 37 weeks in correlation with utero-cervical angle (UCA) and cervical length (CL) measurements. MATERIALS AND METHODS: We conducted a prospective cohort study with UCA and CL measurements in patients with threatened preterm labor (TPL). Primary outcome was differences in UCA and CL measurements in relationship to maternal characteristics and perinatal outcome between groups. Secondary outcome evaluated measurement results and influencing factors for delivery within 7 days, between 1 and 4 weeks and beyond 4 weeks. RESULTS: Overall 152 patients were divided into as study/preterm group (<37 weeks; n = 56) and the control/term group (≥37 weeks; n = 96). Mean gestational age at admission was similar in both groups (30.98 ± 2.83 vs. 30.36 ± 2.63 weeks, p = 0.149) with similar CL (33.9 ± 6.34 vs. 32.02 ± 8.88 mm, p = 0.132), but wider UCA in the preterm group (81.65 ± 16.81° vs. 99.21 ± 22.33°, p < 0.001). Multivariate logistic regression analysis for preterm delivery was significant for nulliparity and UCA measurement. The factor for delivering before 37 gestational weeks within 7 days was the gestational week at admission (p = 0.046). UCA and CL measurements were statistically significant for distinguishing patients for delivery within 7 days and beyond 4 weeks (p = 0.001 for CL and p = 0.0001 for UCA). NPV was found 92.5, 92.2, and 92.3 for UCA >105°, CL ≤30 mm, and Bishop score >3, respectively. CONCLUSION: Combined measurement of TV UCA and CL represents stronger predictors for sPTB ultrasonographically, demonstrating the uterocervical sub-segment maturation before the active onset of labor.


Assuntos
Trabalho de Parto Prematuro , Nascimento Prematuro , Gravidez , Feminino , Recém-Nascido , Humanos , Colo do Útero/diagnóstico por imagem , Estudos Prospectivos , Trabalho de Parto Prematuro/diagnóstico por imagem , Útero , Medida do Comprimento Cervical/métodos
15.
J Perinat Med ; 52(1): 76-80, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37942777

RESUMO

OBJECTIVES: To compare transvaginal (TV) and trans-abdominal (TA) ultrasound assessment of cervical length (CL) at the time of the second-trimester scan for fetal anomalies. METHODS: This was a prospective study including consecutive pregnant women attending the low-risk ultrasound clinic of two fetal medicine centres in Italy. The inclusion criteria were women between 19 + 0 and 22 + 0 weeks of gestation, attending the prenatal ultrasound clinic for the routine second trimester screening for fetal anomalies. The primary outcome was to compare the CL measurement obtained at TV compared to TA ultrasound; the secondary outcome was to report the inter and intra-observer variability of CL measured with the two different approaches. All women underwent TV and TA assessment of the cervix performed by two experienced certified operators, blinded to each other. Intra-class correlation coefficients (ICC) and Bland-Altman analyses were used to analyse the data. RESULTS: Two hundred and fifty women were included in the analysis. All women had anteverted uterus. The mean gestational age at ultrasound was 20.7 ± 0.7 weeks; 1.2 % (3/250) scans were performed at 19 weeks, 49.2 % (123/250) at 20 weeks, 44.8 % (112/250) at 21 weeks and 4.8 % (12/250) at 22 weeks of gestations. Identification of the major landmarks of CL at TA ultrasound was achieved in all the included cases. There was good reliability between CL measured at TA (ICC 0.95, 95 % CI 0.93-0.97 for observer 1 and 0.92 %, 95 % CI 0.89-0.94 for observer 2) and TV ultrasound 0.97, 95 % CI 0.96-0.98 for observer 1 and 0.96, 95 % CI 0.95-0.97 for observer 2). There was also good reliability between the two observers for both the TA and TV assessment of the CL. Mean TA CL was 41.4 ± 5.5 for observer 1 and 40.5 ± 4.8 for observer 2 with no significant differences between the two measurements (mean difference 0.92 mm, 95 % CI -9.7 to 11.2). Likewise, there was no difference between the CL measured at TV ultrasound between the two observers (mean difference -0.83 mm, 95 % CI -5.97 to 4.30). Finally, there was no difference in the mean CL measured at TA compared to TV, either considering the overall population of women (mean difference: -0.43, 955 CI -8.65 to 7.79), or when stratifying the analysis according to the parity status and the operator. CONCLUSIONS: Among experienced operators, there was no difference between TV and TA ultrasound assessment of the CL at the time of the routine anomaly scan for fetal anomaly.


Assuntos
Medida do Comprimento Cervical , Colo do Útero , Gravidez , Feminino , Humanos , Lactente , Masculino , Segundo Trimestre da Gravidez , Colo do Útero/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia , Ultrassonografia Pré-Natal
16.
Hum Reprod ; 39(1): 74-82, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-37994646

RESUMO

STUDY QUESTION: Do characteristics of the lower uterine segment and cervix modify the risk of preterm delivery in uterus transplant (UTx) recipients? SUMMARY ANSWER: The cervical length showed little association with preterm delivery, however, cervical inflammation deserves further exploration as a cause of preterm delivery. WHAT IS KNOWN ALREADY: UTx recipients do not have the risk factors normally used to stratify pregnancies that would benefit from cervical length assessment. In addition, unique factors related to absent tissues, a different blood supply, inflammatory processes of rejection, cervical biopsies, and a different microbiome challenge the normal progressive remodeling of the cervix and thus cervical competence. STUDY DESIGN, SIZE, DURATION: This is a subanalysis of a clinical trial of 20 women undergoing uterus transplantation at Baylor University Medical Center from 2016 to 2020, in addition to two women who received transplantation outside of a research protocol at our institution through September 2022. In this report, the first 16 UTx recipients that achieved live birth are included. PARTICIPANTS/MATERIALS, SETTING, METHODS: The focus of this study was 20 pregnancies that reached the second trimester in 16 women following UTx. We analyzed recipient, transplant, and donor factors to determine if characteristics were associated with delivery outcome. We compared obstetrical outcomes, including planned versus unplanned delivery, by factors such as number of superior venous anastomoses, warm ischemia and cold ischemia times, donor factors including cesarean sections, cervical biopsy results, and cervical ultrasound results. MAIN RESULTS AND THE ROLE OF CHANCE: Planned term deliveries occurred in 44% (8/18) of live births. Of the preterm births, 30% (3/10) were planned and 70% (7/10) were unplanned. Unplanned deliveries occurred in women with spontaneous preterm labor, severe rejection, subchorionic hematoma, and placenta previa. Cervical length in UTx recipients averaged 33.5 mm at 24 weeks and 31.5 mm at 28 weeks, comparable to values from the general population. No relationship was seen between delivery outcome and number of veins used, ischemic time, or number of previous cesarean sections. LIMITATIONS, REASONS FOR CAUTION: The study's small size allows limited conclusions. The obstetric history of all donors was limited to mode of delivery. WIDER IMPLICATIONS OF THE FINDINGS: Cervical length measurements in the UTx population are not expected to deviate from those with a native uterus. While cervical length surveillance remains important, attention must be paid to the results of cervical biopsies which are obtained to monitor rejection. Inflammatory processes seem most predictive of preterm delivery. STUDY FUNDING/COMPETING INTEREST(S): No funding was provided for this study. The authors report no conflicts of interest. TRIAL REGISTRATION NUMBER: NCT02656550.


Assuntos
Nascimento Prematuro , Feminino , Humanos , Recém-Nascido , Gravidez , Colo do Útero/diagnóstico por imagem , Nascimento Prematuro/etiologia , Fatores de Risco , Transplantados , Útero/diagnóstico por imagem
17.
Clin Radiol ; 79(2): e264-e272, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37926648

RESUMO

AIM: To determine the associations of intravoxel incoherent motion (IVIM) parameters with expression of programmed cell death-1 (PD-1) and programmed cell death ligand-1 (PD-L1), and evaluate the performance of the combined model established based on IVIM and clinicopathological parameters in predicting PD-L1and PD-1 status of cervical cancer (CC) patients. MATERIALS AND METHODS: Seventy-eight consecutive CC patients were enrolled prospectively and underwent magnetic resonance imaging (MRI) including IVIM. IVIM quantitative parameters were measured, compared, and correlated with PD-L1 and PD-1 expression. Independent factors related to PD-L1 and PD-1 positivity were identified and were used to establish the combined model. The combined model's diagnostic performance was evaluated using the receiver operating characteristic (ROC) analysis. The Shapley additive explanation (SHAP) algorithm was used to explain the contribution of each parameter in the combined model. RESULTS: The real diffusion coefficient (D) value was significantly lower in the PD-L1-positive group than in the PD-L1-negative group (0.64 ± 0.12 versus 0.72 ± 0.11, p=0.021). The PD-1-positive and PD-1-negative groups showed similar trends (0.63 ± 0.13 versus 0.73 ± 0.09, p=0.003). Parametrial invasion, lymph node status, pathological grade, FIGO (International Federation of Gynecology and Obstetrics) staging, and D values were independently associated with PD-L1 and PD-1expression. A combined model incorporating these parameters showed good discrimination with the sensitivity, specificity of 90.9%, 82.6% for PD-L1, and 93.5%, 72% for PD-1. According to the SHAP value, FIGO staging and pathological grade were the most influential features of the prediction model. CONCLUSION: IVIM parameters were found to correlate with PD-L1 and PD-1 expression. The combined model, incorporating parametrial invasion, lymph node status, pathological grade, FIGO staging, and D values, showed good discrimination in predicting PD-L1 and PD-1 status, providing the basis for CC immunotherapy.


Assuntos
Antígeno B7-H1 , Receptor de Morte Celular Programada 1 , Neoplasias do Colo do Útero , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Colo do Útero/diagnóstico por imagem , Colo do Útero/patologia , Receptor de Morte Celular Programada 1/metabolismo , Antígeno B7-H1/metabolismo , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/metabolismo , Neoplasias do Colo do Útero/patologia , Imageamento por Ressonância Magnética
18.
Int J Gynaecol Obstet ; 164(3): 951-958, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37675927

RESUMO

OBJECTIVE: To assess the impact of the introduction of universal transvaginal cervical screening and certification on the quality of cervical length ultrasound images. METHODS: The present study included a retrospective cohort of singleton pregnancies that underwent transvaginal cervical length measurement at the anatomical scan (180/7 and 236/7 weeks) before (period A, 2015-2017) and after (period B, 2017-2019) the introduction of universal transvaginal cervical length screening. Independent observers blindly evaluated the images obtained for cervical length using a qualitative scoring method based on five criteria, according to the Fetal Medicine Foundation. RESULTS: In all, 6013 patients met the inclusion criteria, 3333 in period A and 2680 in period B. Maternal characteristics and risk factors for preterm birth were similar between the two periods. The acceptance of transvaginal cervical length measurement in period B was 95.5% in the overall cohort and 100% in the subgroup of high-risk patients. The quality score was significantly higher in period B than in period A. Among the image quality criteria, the anterior/posterior ratio, the correct magnification of the images, and the calipers' placement contributed significantly to the improved quality score in period B. Most of the sonographers performed better in period B, irrespective of the years of experience, but certificate holders obtained higher scores than non-certified sonographers, particularly those in mid-career. The identification of short cervix was significantly higher in period B than in period A. CONCLUSION: The implementation of universal transvaginal cervical length screening and the certification process are associated with improved quality of cervical length images, even among expert sonographers and in the presence of anatomical pitfalls.


Assuntos
Nascimento Prematuro , Neoplasias do Colo do Útero , Gravidez , Feminino , Humanos , Recém-Nascido , Nascimento Prematuro/prevenção & controle , Colo do Útero/diagnóstico por imagem , Estudos Retrospectivos , Detecção Precoce de Câncer , Neoplasias do Colo do Útero/diagnóstico por imagem , Medida do Comprimento Cervical/métodos , Certificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...